INA199C1DCKR Overview

The INA199C1DCKR is a highly accurate, low-power current and voltage sensor IC from Texas Instruments. It offers a wide range of features and applications, making it an ideal solution for energy management and monitoring systems.

Key Features:

INA199C1DCKR

INA199C1DCKR

  • Measures both current and voltage
  • High accuracy of ±1.5% for current and ±0.5% for voltage
  • Ultra-low power consumption of 200 nA
  • Wide input voltage range of 0V to +10V
  • Current measurement range of 0A to ±40A
  • Voltage measurement range of 0V to +65V
  • Compact, space-saving MSOP-8 package

Applications:

The INA199C1DCKR finds wide application in various industries, including:

  • Battery management
  • Power supply monitoring
  • Solar panel monitoring
  • Motor control
  • Lighting control
  • HVAC systems
  • Automotive electronics

Power Consumption:

The INA199C1DCKR: A Comprehensive Guide to Maximizing Energy Efficiency

The INA199C1DCKR consumes an ultra-low power of 200 nA (typical), making it suitable for battery-operated applications. Its low power consumption significantly reduces system power losses.

Input Voltage Range:

The INA199C1DCKR: A Comprehensive Guide to Maximizing Energy Efficiency

The device can operate with an input voltage range of 0V to +10V, making it compatible with a wide range of systems. This feature allows the INA199C1DCKR to monitor both positive and negative voltages.

The INA199C1DCKR: A Comprehensive Guide to Maximizing Energy Efficiency

Current Measurement Range:

The INA199C1DCKR measures current in the range of 0A to ±40A. Its high accuracy of ±1.5% ensures precise current readings. This capability enables accurate monitoring of currents in various applications, such as battery charging and motor control.

Voltage Measurement Range:

The INA199C1DCKR: A Comprehensive Guide to Maximizing Energy Efficiency

Additionally, the INA199C1DCKR measures voltage in the range of 0V to +65V. With an accuracy of ±0.5%, it provides reliable voltage monitoring for power supplies, batteries, and other voltage sources.

How to Use the INA199C1DCKR

Step-by-Step Guide:

  1. Connect the INA199C1DCKR: Place the IC on a PCB and connect the input voltage (V+) to the V+ pin, the input voltage (V-) to the V- pin, and the current sense resistor to the SENSE+ and SENSE- pins.
  2. Provide Power: Apply a voltage between 2.7V and 5.5V to the VCC pin.
  3. Configure the Gain: Set the gain of the current measurement channel by selecting a suitable value for the current sense resistor.
  4. Read the Output: The output voltage at the OUT pin represents the measured current or voltage. The output can be directly connected to an analog-to-digital converter (ADC) for digital processing.

Tips and Strategies for Effective Use:

  • Place a decoupling capacitor close to the VCC pin for stable operation.
  • Use a low-value current sense resistor to minimize power loss.
  • Protect the device from overvoltage and overcurrent conditions.
  • Calibrate the INA199C1DCKR for optimal accuracy.

Table Summary and Analysis:

| Characteristic | INA199C1DCKR |
|---|---|---|
| Input Voltage Range | 0V to +10V |
| Current Measurement Range | 0A to ±40A |
| Voltage Measurement Range | 0V to +65V |
| Accuracy (Current) | ±1.5% (typical) |
| Accuracy (Voltage) | ±0.5% (typical) |
| Power Consumption | 200 nA (typical) |
| Package | MSOP-8 |

Table: INA199C1DCKR Specifications

Parameter Minimum Typical Maximum
Supply Voltage (VCC) 2.7V 3V 5.5V
Current Measurement Range -40A 0A 40A
Voltage Measurement Range 0V -0.1V 65V
Current Error -1.5% 0% 1.5%
Voltage Error -0.5% 0% 0.5%
Output Voltage Low (IIN 0V 100mV 200mV
Output Voltage High (IIN > 10A) VCC-200mV VCC-100mV VCC

Table: INA199C1DCKR Error Characteristics

Additional Features and Benefits:

  • Shunt-Calibration: The INA199C1DCKR can perform shunt calibration to correct for errors introduced by the current sense resistor.
  • Overvoltage Protection: The device is protected against overvoltage conditions on the V+ and V- pins.
  • Fault Indication: An open-drain FAULT pin indicates any error conditions.